Wound, annealed and precision cut into two matching C halves — coils are wound separately and slipped on, shortening assembly time for cut-core transformers.
CD cores are wound and vacuum annealed, then precision cut into two identical C-shaped halves. The two halves form a closed magnetic circuit with a tight, low-reluctance butt joint after face grinding.
Because the core opens into two halves, the coil can be wound separately on a bobbin and simply slipped over the core — no winding the coil through a closed window. This shortens production lead time and simplifies assembly for cut-core transformers and rectifier power supplies.
| Material | Baosteel grain-oriented silicon steel |
|---|---|
| Structure | Wound and annealed · precision cut into 2 × C halves |
| Heat treatment | Vacuum annealing (stress relief, magnetic stabilization) |
| Cut-face finish | Precision ground / milled |
| Customization | Dimensions, material grade and magnetic performance built to your drawing or sample |
Need the full dimensional range? Ask us — we will send the spec sheet for your size.